{"generated_at":"2026-10-14T20:07:22+00:00","item":{"added_at":"2026-08-19","analysis_method":"independent_manual_review_2026-10-10","assessment_status":"provisional","auth_posture":"auth_required","category":"Web Connector","confidence":"medium","description":"smart-me connects Claude to meters, charging stations, and building billing. Read consumption or configure devices, folders, tariffs, and self-consumption billing. Writes require confirmation; long value histories require a Professional licence.","did":"464bffe6-c3f1-4649-96dd-528351da8101","documentation_url":"https://doc.smart-me.com/interfaces/ai-connector","editorial_description":{"extended_description":"An existing smart-me account is required. Folder or charger deletion uses a two-step name-confirmation workflow. Tools can check Swiss ZEV billing configurations before invoicing.","schema_version":1,"summary":"smart-me connects Claude to meters, charging stations, and building billing.\nRead consumption or configure devices, folders, tariffs, and self-consumption billing.\nWrites require confirmation; long value histories require a Professional licence."},"homepage_url":"","icon":"","id":"464bffe6-c3f1-4649-96dd-528351da8101","installs":0,"last_scanned":"","license":"","long_description":"An existing smart-me account is required. Folder or charger deletion uses a two-step name-confirmation workflow. Tools can check Swiss ZEV billing configurations before invoicing.","manual_assessment":"high","manual_review":{"all_findings":[{"evidence":"The inventory explicitly deletes operational energy resources; the description documents a two-step exact-name confirmation for folder/station deletion.","reasoning":"These operations can remove live device or site configuration.","risk_type":"data_deletion","severity":"high","title":"Deletes charging stations, folders and load-management groups","triggering_tools_or_skills":["delete_charging_station","delete_folder","delete_load_management_group"]},{"evidence":"The connector can switch relays, command chargers, set current limits and change tariffs/billing configuration.","reasoning":"These actions affect physical electrical equipment and production billing behavior.","risk_type":"deployment_infrastructure","severity":"high","title":"Controls electrical devices, charging and billing infrastructure","triggering_tools_or_skills":["execute_device_action","send_charging_station_command","set_load_management_dynamic_current","set_load_management_group","update_charging_station_settings","update_billing_configuration","update_virtual_tariff"]}],"assessment_status":"provisional","auth_and_scopes":"Authentication acts with the user's smart-me permissions over meters, relays, charging stations, load management and billing; writes are confirmed and destructive actions use two-step exact-name confirmation.","blocked_missing_evidence":null,"confidence":"medium","displayed_risk":"high","evidence_completeness":"complete","manual_overall_risk":"high","official_sources":[{"accessed_at":"2026-10-10T20:24:37Z","url_or_path":"plutosecurity/plutonium@b749c8dc43536c794409be9805edd48063f045e2:app/data/conn/claudesec/464bffe6-c3f1-4649-96dd-528351da8101.json","what_it_proves":"Candidate PR #125 record identity (name \"smart-me\", publisher, type web_connector) and 47 stored tool names; no tool descriptions stored"},{"accessed_at":"2026-09-22T10:46:07Z","url_or_path":"https://api.anthropic.com/api/directory/servers?verified_tier=anthropic,partner,community (snapshot claude-directory-all-tiers-2026-09-22.json)","what_it_proves":"Official Claude Directory listing https://claude.ai/directory/464bffe6-c3f1-4649-96dd-528351da8101: complete tool_names inventory (47 tools), remote streamable-http endpoint https://mcp.smart-me.com/mcp, auth_posture auth_required, directory tier community"}],"primary_reason":"smart-me can delete and command live electrical, charging and billing infrastructure.","provisional_risk":null,"publication_recommendation":"accept","requires_runtime_verification":true,"review_key":"claude:464bffe6-c3f1-4649-96dd-528351da8101","reviewed_at":"2026-10-10","reviewer_notes":"Preserve explicit confirmation, safety bounds and exact-name deletion confirmation.","risk_domains":{"arbitrary_network_access":"false","authz_ambiguity":"false","browser_control":"false","credential_or_admin_actions":"true","deletes_data":"true","deployment_or_infrastructure":"true","dynamic_hidden_actions":"false","filesystem_or_repo_access":"false","forwards_data_to_third_party":"true","modifies_data":"true","persistent_credentials":"true","prompt_injection_exposure":"false","provenance_uncertainty":"true","reads_private_data":"true","runs_code_or_queries":"false","sends_messages_as_user":"false","spends_or_moves_money":"false"},"tools_or_skills_reviewed":47,"tools_or_skills_total":47},"name":"smart-me","needs_runtime_verification":true,"plutonium_url":"https://plutonium.pluto.security/detail.html?planet=claudesec&did=464bffe6-c3f1-4649-96dd-528351da8101&utm_source=plutonium_analysis_skill&utm_medium=claude_skill&utm_campaign=connector_risk_assessment","privacy_policy_url":"https://docs.google.com/document/d/1eYB81kh7pywKiMbUsUoDB9gZKse0ygGFebSoMecGQ1Q/export?format=pdf","provisional_risk":null,"publication_recommendation":"accept","publisher":"smart-me","publisher_url":"https://www.smart-me.com/","remote_url":"https://mcp.smart-me.com/mcp","repository_url":"","risk":"high","risk_severity":"high","security_risks":[{"description":"This connector can permanently remove data or resources. Review findings: These operations can remove live device or site configuration.","evidence":"Deletes charging stations, folders and load-management groups: The inventory explicitly deletes operational energy resources; the description documents a two-step exact-name confirmation for folder/station deletion.","manual_risk_type":"data_deletion","remediation":{"block_tool_categories":["destructive"],"steps":["Disable destructive tools unless deletion is an explicit workflow requirement.","Require human confirmation and verified backups before deletion."]},"risk_type":"deletes_data","severity":"high","title":"Deletes charging stations, folders and load-management groups","triggering_tools":["delete_charging_station","delete_folder","delete_load_management_group"]},{"description":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior.","evidence":"Controls electrical devices, charging and billing infrastructure: The connector can switch relays, command chargers, set current limits and change tariffs/billing configuration.","manual_risk_type":"deployment_infrastructure","remediation":{"block_tool_categories":["code_execution","state_change"],"steps":["Default to a sandbox or staging environment.","Require code review, human approval, audit logging, and a tested rollback path for production changes."]},"risk_type":"code_deployment","severity":"high","title":"Controls electrical devices, charging and billing infrastructure","triggering_tools":["execute_device_action","send_charging_station_command","set_load_management_dynamic_current","set_load_management_group","update_charging_station_settings","update_billing_configuration","update_virtual_tariff"]}],"signature_status":"unknown","source_code_reviewed":false,"support_url":"support@smart-me.com","tags":["code_deployment","deletes_data","network_access","oauth_required","web_connector"],"tools":[{"description":"","name":"add_vewa_cost_period"},{"description":"","name":"check_zev_configuration"},{"description":"","name":"create_billing_property"},{"description":"","name":"create_folder"},{"description":"","name":"delete_charging_station","risk":{"category":"destructive","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can permanently remove data or resources. Review findings: These operations can remove live device or site configuration."}},{"description":"","name":"delete_folder","risk":{"category":"destructive","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can permanently remove data or resources. Review findings: These operations can remove live device or site configuration."}},{"description":"","name":"delete_load_management_group","risk":{"category":"destructive","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can permanently remove data or resources. Review findings: These operations can remove live device or site configuration."}},{"description":"","name":"derive_solar_tariff_prices"},{"description":"","name":"enable_fix_cable_lock"},{"description":"","name":"execute_device_action","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}},{"description":"","name":"get_billing_configuration"},{"description":"","name":"get_charging_history"},{"description":"","name":"get_charging_station_settings"},{"description":"","name":"get_charging_status"},{"description":"","name":"get_device"},{"description":"","name":"get_folder_tree"},{"description":"","name":"get_latest_values"},{"description":"","name":"get_load_management_group"},{"description":"","name":"get_load_management_group_state"},{"description":"","name":"get_tariff_consumption"},{"description":"","name":"get_tariff_distribution"},{"description":"","name":"get_tariff_time"},{"description":"","name":"get_value_history"},{"description":"","name":"get_values_at"},{"description":"","name":"get_virtual_tariffs"},{"description":"","name":"list_billing_properties"},{"description":"","name":"list_charging_stations"},{"description":"","name":"list_configurations"},{"description":"","name":"list_device_actions"},{"description":"","name":"list_devices"},{"description":"","name":"list_load_management_groups"},{"description":"","name":"list_vewa_cost_periods"},{"description":"","name":"load_configuration"},{"description":"","name":"move_to_folder"},{"description":"","name":"rename"},{"description":"","name":"resolve_meters"},{"description":"","name":"save_configuration"},{"description":"","name":"send_charging_station_command","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}},{"description":"","name":"set_charging_station_idle_image"},{"description":"","name":"set_load_management_dynamic_current","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}},{"description":"","name":"set_load_management_group","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}},{"description":"","name":"set_tariff_time"},{"description":"","name":"update_billing_configuration","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}},{"description":"","name":"update_billing_property"},{"description":"","name":"update_charging_station_settings","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}},{"description":"","name":"update_vewa_cost_period"},{"description":"","name":"update_virtual_tariff","risk":{"category":"code_execution","level":"high","recommendation":"Follow the connector-level remediation and require approval for consequential actions.","why":"This connector can deploy code or change infrastructure and production environments. Review findings: These actions affect physical electrical equipment and production billing behavior."}}],"tools_count":47,"transport":"streamable-http","type":"web_connector","url":"https://claude.ai/directory/464bffe6-c3f1-4649-96dd-528351da8101","uuid":"a3464b1c-8aab-5079-bfcf-a4573e89ed63","verification_tier":"community","version":""},"query_key":"smart me","schema_version":1,"status":"match"}
